User manual
Pull Rod Box Laser Cleaning Machine Security Information
1.Laser protection and safety
The Portable pull rod box laser cleaning machine has an output wavelength of 1064nm (invisible light) and an average laser output power of over 100W (peak power over 10KW), which is IV Grade laser, can not only on the retina and the cornea causes irreversible damage, but also burn the skin, its reflection and scattered light may also be made to the human body for injury, please wear OD4 + grade laser protective glasses during use .
2. Electrical safety
Pull Rod Box Laser Cleaning Machine before connecting the power supply, check the power voltage (220V) and machine power interface,and ensure that it is correct can be on the electricity.
Pull Rod Box Laser Cleaning Machine improper connection to the power supply may cause damage to the laser and the washer.
Pull Rod Box Laser Cleaning Machine ground wire is required during use, and disconnection of ground wire may cause personal injury to the operator.
Pull Rod Box Laser Cleaning Machine do not work in high temperature, high humidity and high pressure environment, otherwise it may cause short circuit and laser temperature alarm, and affect the clearance normal washer service and laser life.
3. Operating specifications
(1) When the power is on, do not directly view the hole of the cleaning head;
(2) avoid cleaning the hole and the eyes on the same level;
(3) Do not use the laser washer in a dark environment;
(4) When debugging calibration or focusing, please start at low power, and then increase to the high power work.
Pull Rod Box Laser Cleaning Machine Operating Instructions
- Open the upper cover of the chassis, remove the power cord, insert one end into the power interface next to the cooling air duct above the chassis, and connect the 220V AC power supply on the other end.
- Remove the laser head, hold the handle by hand, exit the light outlet down, and press the red power switch to the power state.
- Press the red trigger switch. When the trigger switch and the handle button indicator are on, it can turn on.
- Remove the handheld control card and open it. For example, English letter plus numbers in the lower left corner of the control card opening interface indicates that the control card has been successfully connected to the machine, otherwise the failure state.
- After the control card is connected to the machine, the required parameters can be set by the handheld control card.
- he handle button is a section, press and maintain as focus red light and the current scanning range, and the laser is pressed twice and maintained (the continuous press interval is <0.35S, and the laser interval is> 0.35S)
Fault Measures and Treatment Measures
Common faults and treatment measures
Order Number | Common faults and problems | Possible causes and solutions |
1 | The handheld control card failed to connect to the host | The control card and the host did not successfully match the address, and the host address needs to be modified |
2 | No focus red light & no red light | The key failure or red light failure, you need to return to the factory for repair |
3 | The effect is inconsistent with the same conditions | Power attenuation or armor cable bending is serious, power attenuation in the normal range is normal conditions, the bending diameter of armor cable should not be too small |
4 | Normal power supply is no alarm, but not light | Key failure or laser failure shall be returned to the factory for repair |
5 | Temperature alarm | The ambient temperature is too high to operate at the appropriate operating temperature |
6 | Other alarm | Laser fault, need to return to the factory for repair |